There are two types of heat pumps that are commonly used today. They are known as air-to-air HP and geothermal HP. The former uses the outdoor air whereas the latter uses the underground (water or earth) temperature as its source of heating or cooling. The air-to-air type is more economical and is popular in residential and commercial buildings applications.
These equipments work on the principle that heat will move from higher temperature to lower temperature. Therefore, a heat transfer coil that is kept a low temperature compared to its surrounding will take away the heat from the surrounding, hence cooling the space. To transfer heat to the surrounding, the heat transfer device is heated up to a higher temperature than the surrounding.
This system is designed to be used for cooling the space during summer and heating during winter. The coils at the indoor and outdoor become evaporator or condenser depending on the mode of operation. If it is operating in cooling mode, the indoor coil behaves as evaporator and outdoor as condenser.
In heating mode, the indoor coil becomes a condenser and the outdoor coil evaporator. This is accomplished without moving the coils around by using a reversing valve known as four-way valve which reverses the flow of the refrigerant.
HP Operation
The HP that is commonly used is known as vapor compression refrigeration machine. An absorption machine can also be used but
is not as common. The vapor compression cycle is used in our refrigerators and large industrial refrigeration systems. The
diagram below shows the basic schematic of operation of a typical HP in cooling mode during summer.
During winter, heating mode is activated and the direction of the refrigerant is reversed after leaving the compressor. Take note that the flow of the refrigerant in the compressor remains the same. This reversal of flow is achieved by using a reversing valve.
The change of flow causes the room coil to become a condenser and the outdoor coil an evaporator. The
fan that blows the room air across the condenser coil causes heat to be released into the room. The heating cycle is
illustrated in the figure below.
In winter condition where temperature drops below -7°C, the heat pump heating cycle becomes less efficient as the outdoor ambient temperaure drops below freezing point. When the outdoor coil freezes with a layer of ice, the unit will have to run cooling mode to defrost the ice that accumulate on the coil.
During this time, the unit will be extracting heat from the room to the outdoor. Most controllers will stop the indoor fan from blowing the cold air into the space. This is one of the main disadvantage of this type of system when used in extreme winter condition.
Heat Pump Maintenance
Some of the actions that you can do to maintain you HP to ensure it continuous operations are listed below.